NEO-Flat cable

NEO-Flat cable
Product Detailed
Related Categories:Power Cables
Cu/Rubber/Rubber 1.ISO9001,ISO14001,CCC 2.China Biggest cable manufactory 3.7000 staffs 4.Standard:GB JB IEC BS VDE JIS etc

Application

Neoprene type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units.These cables are also available for export with UL-approval.Installation notesCables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface.For this purpose, the corresponding fitting instructions should be followed.1.Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface of two cable trollys must be wider than the double thickness of a cable-packet.2.During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be buildedsuccessively so that the biggest cross-section is laying on the top.3.Further, be careful of a symmetrical load distribution.4.In case of multicore flat cables with small cross-section, smaller than 2,5 mm², is very critical due to its low tensile stress. In such case, you should add 10% reserve wire for calculation.

Construction

Conductor:Bare copper, stranded to DIN VDE 0295,BS 6360 cl. 5 and IEC 60228, fine or extra fine wire stranded according to different cross-sections:1 to 25 mm² - class 6, col. 4 35 to 95 mm² - class 5

Core insulation:Special rubber core insulation GI1, to DIN VDE 0207 part 20

Core identification:Core identification up to 5 cores, colour code to DIN VDE 0293 7 cores and above with number printing, Cores laying parallel

Green-yellow earth core

Outer sheath:Special rubber outer sheath 5GM2, to DIN VDE 0207 part 21

Marking:Manufacture name (trademark) and type, Production year/week or batch number ,Metre-marked.

Parameters

AWG

Cross-section

mm²

Cu content

kg/km

Outer diameter approx.

mm

Weight approx.

kg/km

164G 1.558.05.9X16.2234.0
165G 1.572.05.9X23.7304.0
1624G 1.5346.013.0X56.01290.0
144G 2.596.07.2X19.6316.0
145G 2.5120.07.2X27.8391.0
1424G 2.5576.015.5X66.81480.0
124G 4154.08.8X24.2506.0
127G 4269.08.8X42.5851.0
104G 6230.09.6X27.4661.0
107G 6403.09.6X47.21004.0
84G 10384.010.4X30.81027.0
85G 10480.010.4X41.61170.0
64G 16614.011.6X35.61430.0
44G 25960.014.1X45.81890.0
24G 351344.015.8X50.82460.0
14G 501920.018.6X60.23385.0
2/04G 702688.021.0X68.04480.0
3/04G 753648.024.1X78.65990.0
4/04G 1204608.025.5X84.27240.0

G = with green-yellow earth core;x = without green-yellow earth core.

Technical

1.Rated voltage:U0/U 300/500V

2.Test voltage:3000 V

3.Bending radius:10 x cable diameter

4.Temperature range:flexing -25°C to +60°C;fixed installation -40°C to +80°C

5.cold-resistant,Extensively oil resistant, Chemical Resistance ,High flexibility Packeting possibility:Test according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)

6.Radiation resistance:up to 50x106 cJ/kg (up to 50 Mrad)